The Graecus GD Mini Super Silent series is a range of compact diesel generators suitable for professional, agricultural, commercial and residential backup power applications.
Available in three models – GD7100, GD9900 and GD12100 – the series offers different power capacities to accommodate a variety of electrical requirements.
The combination of a sound-insulated enclosure, digital automatic voltage regulation and electric starting makes the series a practical choice for applications where an independent power supply and reduced operating noise are important.
Alsidig strømforsyning til forskellige brancher
The Graecus GD Mini Super Silent series is suitable for users looking for an independent or supplementary source of electricity without investing in a larger stationary industrial generator.
Typiske anvendelsesområder omfatter:
- Landbrug: Strømforsyning til kompatible pumper, elværktøj, belysning og udstyr på gårde og landbrugsanlæg.
- Byggeri: Providing temporary electricity for power tools and compatible equipment on construction sites.
- Værksteder: Understøtter vedligeholdelse, reparation og service, hvor netstrøm ikke er tilgængelig.
- Erhvervsejendomme: Nødstrøm til udvalgt elektrisk udstyr og vigtige driftsfunktioner.
- Private boliger: Supplying selected household circuits during power outages through a correctly installed electrical system.
- Ejendomsvedligeholdelse: Strøm til vedligeholdelsesopgaver på steder uden nem adgang til elnettet.
- Afsidesliggende steder: Strøm til midlertidige installationer og arbejdsområder uden permanent eltilslutning.
The suitability of each generator depends on the total power demand, starting current and distribution of connected electrical loads.
Compact design and flexible positioning
The enclosed design of the Graecus GD Mini Super Silent series makes it a practical option for applications where available installation space is limited.
When selecting a generator, physical dimensions and weight should be considered alongside electrical performance. This is particularly relevant for contractors, agricultural businesses and maintenance companies that may need to transport their equipment between different locations.
The three models have different dimensions and weights, allowing customers to consider both electrical requirements and practical installation conditions when selecting a generator.
Appropriate handling and transport equipment must be used when relocating the generator.
Adequate space must always be provided for ventilation, exhaust gas dispersal, operation and maintenance.
Sound-insulated enclosure for reduced operating noise
A silent diesel generator can be particularly beneficial in locations where operating noise is an important consideration.
The Graecus Super Silent enclosure is designed to reduce operating noise compared with an open-frame generator design.
This makes the series relevant for applications near agricultural facilities, workplaces, commercial buildings and residential properties, provided that the generator is installed in a suitable outdoor location.
The enclosed construction also separates the internal mechanical and electrical components from the surrounding working environment.
Det faktiske støjniveau afhænger af modellen, den elektriske belastning, installationsstedet og omgivelserne.
Digital automatisk spændingsregulering (DAVR)
The GD Mini Super Silent series features digital automatic voltage regulation (DAVR), which helps regulate the generator’s output voltage as connected electrical loads change.
Det gør det muligt at forsyne forskelligt kompatibelt elektrisk udstyr inden for generatorens specificerede driftsgrænser.
When selecting equipment to connect to the generator, both continuous power demand and temporary starting loads must be considered.
Electric motors, compressors and pumps may require significantly more power during start-up than during normal operation. Correct generator sizing is therefore important to ensure that the selected equipment can operate within the generator’s available capacity.
Enfasede og trefasede elektriske tilslutninger
The generators feature both single-phase and three-phase electrical connections, providing flexibility when supplying different types of electrical equipment.
Schuko- og industrielle CEE-stikkontakter gør det muligt at tilslutte kompatibelt elværktøj, maskiner og andet udstyr direkte.
ABB-automatsikringer er monteret for at beskytte de elektriske kredsløb.
The total connected electrical load must remain within the generator’s rated capacity, individual socket ratings and permitted phase-loading limits.
When combining single-phase and three-phase equipment, the distribution of electrical loads must also be considered.
Elektrisk nøglestart
The GD Mini Super Silent generators feature an electric key-start system for straightforward starting and operation.
This is a practical feature for professional users who require an independent power supply for temporary work or backup applications.
Regular inspection and maintenance should be carried out in accordance with the manufacturer’s instructions to help maintain reliable operation.
Nødstrøm med ATS som tilbehør
The Graecus GD Mini Super Silent series supports connection to a compatible external automatic transfer switch (ATS).
When correctly installed and configured, an ATS system can enable automatic backup power operation during a mains electricity failure.
This functionality can be particularly relevant for agricultural facilities, workshops, commercial buildings and residential properties where maintaining selected electrical functions during power interruptions is important.
Ekstern ATS er tilbehør, og kompatibiliteten skal bekræftes inden installation.
Choosing the right diesel generator
The Graecus GD Mini Super Silent series is available in three models:
- GD7100 MINI SUPER SILENT
- GD9900 MINI SUPER SILENT
- GD12100 MINI SUPER SILENT
When choosing between the three models, consider the following:
- Continuous electrical power requirements.
- Starting loads from connected equipment.
- Single-phase and three-phase power requirements.
- The number of devices operating simultaneously.
- Fuel consumption and fuel tank capacity.
- Generator dimensions and weight.
- Installation and transportation requirements.
Refer to the Technical Specifications section for a detailed comparison of the available models.
Please contact Graecus Nordic to confirm the generator’s rated electrical output and suitability for your specific power requirements before ordering.
Installation og sikker drift
Diesel generators must be operated outdoors in a suitable location, away from doors, windows and ventilation openings, with adequate ventilation and safe dispersal of exhaust gases.
Generatorer må ikke anvendes inde i bygninger, garager eller andre lukkede rum.
Tilslutning til en bygnings elektriske installation skal udføres af en kvalificeret elektriker.
Always follow the manufacturer’s operating, installation and maintenance instructions.