The Graecus GD Mini Super Silent diesel generator series offers a flexible power solution for agriculture, construction, workshops and residential backup power applications.

15–28 LFuel tank capacity (L)
178–336 kgGross weight (kg)
8–15.4 kWEngine power (kW)

Available in three models, the series combines a sound-insulated enclosure, digital voltage regulation and versatile electrical connections.

Beskrivelse

Silent diesel generator for professional and backup power

The Graecus GD Mini Super Silent series is a range of compact diesel generators suitable for professional, agricultural, commercial and residential backup power applications.

Available in three models – GD7100, GD9900 and GD12100 – the series offers different power capacities to accommodate a variety of electrical requirements.

The combination of a sound-insulated enclosure, digital automatic voltage regulation and electric starting makes the series a practical choice for applications where an independent power supply and reduced operating noise are important.

A versatile power supply for different industries

The Graecus GD Mini Super Silent series is suitable for users looking for an independent or supplementary source of electricity without investing in a larger stationary industrial generator.

Typical applications include:

  • Agriculture: Supplying compatible pumps, electrical tools, lighting and equipment on farms and at agricultural facilities.
  • Construction: Providing temporary electricity for power tools and compatible equipment on construction sites.
  • Workshops: Supporting maintenance, repair and service operations where mains electricity is unavailable.
  • Commercial properties: Providing backup power for selected electrical equipment and essential operations.
  • Residential properties: Supplying selected household circuits during power outages through a correctly installed electrical system.
  • Property maintenance: Providing electricity for maintenance tasks in locations without convenient access to the mains supply.
  • Remote locations: Supporting temporary installations and work areas where a permanent electrical connection is unavailable.

The suitability of each generator depends on the total power demand, starting current and distribution of connected electrical loads.

Compact design and flexible positioning

The enclosed design of the Graecus GD Mini Super Silent series makes it a practical option for applications where available installation space is limited.

When selecting a generator, physical dimensions and weight should be considered alongside electrical performance. This is particularly relevant for contractors, agricultural businesses and maintenance companies that may need to transport their equipment between different locations.

The three models have different dimensions and weights, allowing customers to consider both electrical requirements and practical installation conditions when selecting a generator.

Appropriate handling and transport equipment must be used when relocating the generator.

Adequate space must always be provided for ventilation, exhaust gas dispersal, operation and maintenance.

Sound-insulated enclosure for reduced operating noise

A silent diesel generator can be particularly beneficial in locations where operating noise is an important consideration.

The Graecus Super Silent enclosure is designed to reduce operating noise compared with an open-frame generator design.

This makes the series relevant for applications near agricultural facilities, workplaces, commercial buildings and residential properties, provided that the generator is installed in a suitable outdoor location.

The enclosed construction also separates the internal mechanical and electrical components from the surrounding working environment.

Actual noise levels depend on the selected model, electrical load, installation location and surrounding conditions.

Digital automatic voltage regulation (DAVR)

The GD Mini Super Silent series features digital automatic voltage regulation (DAVR), which helps regulate the generator’s output voltage as connected electrical loads change.

This allows the generator to supply a variety of compatible electrical equipment within its specified operating limits.

When selecting equipment to connect to the generator, both continuous power demand and temporary starting loads must be considered.

Electric motors, compressors and pumps may require significantly more power during start-up than during normal operation. Correct generator sizing is therefore important to ensure that the selected equipment can operate within the generator’s available capacity.

Single-phase and three-phase electrical connections

The generators feature both single-phase and three-phase electrical connections, providing flexibility when supplying different types of electrical equipment.

Schuko and industrial CEE sockets allow compatible electrical tools, machinery and other equipment to be connected directly.

ABB circuit breakers are fitted to provide electrical circuit protection.

The total connected electrical load must remain within the generator’s rated capacity, individual socket ratings and permitted phase-loading limits.

When combining single-phase and three-phase equipment, the distribution of electrical loads must also be considered.

Electric key start

The GD Mini Super Silent generators feature an electric key-start system for straightforward starting and operation.

This is a practical feature for professional users who require an independent power supply for temporary work or backup applications.

Regular inspection and maintenance should be carried out in accordance with the manufacturer’s instructions to help maintain reliable operation.

Backup power with optional ATS

The Graecus GD Mini Super Silent series supports connection to a compatible external automatic transfer switch (ATS).

When correctly installed and configured, an ATS system can enable automatic backup power operation during a mains electricity failure.

This functionality can be particularly relevant for agricultural facilities, workshops, commercial buildings and residential properties where maintaining selected electrical functions during power interruptions is important.

The external ATS is optional, and compatibility must be confirmed before installation.

Choosing the right diesel generator

The Graecus GD Mini Super Silent series is available in three models:

  • GD7100 MINI SUPER SILENT
  • GD9900 MINI SUPER SILENT
  • GD12100 MINI SUPER SILENT

When choosing between the three models, consider the following:

  • Continuous electrical power requirements.
  • Starting loads from connected equipment.
  • Single-phase and three-phase power requirements.
  • The number of devices operating simultaneously.
  • Fuel consumption and fuel tank capacity.
  • Generator dimensions and weight.
  • Installation and transportation requirements.

Refer to the Technical Specifications section for a detailed comparison of the available models.

Please contact Graecus Nordic to confirm the generator’s rated electrical output and suitability for your specific power requirements before ordering.

Installation and safe operation

Diesel generators must be operated outdoors in a suitable location, away from doors, windows and ventilation openings, with adequate ventilation and safe dispersal of exhaust gases.

Generators must not be operated inside buildings, garages or other enclosed spaces.

Connection to a building’s electrical installation must be carried out by a qualified electrician.

Always follow the manufacturer’s operating, installation and maintenance instructions.

SpecificationGD7100GD9900GD12100
Single-phase voltage (V)220/230220/230220/230
Three-phase voltage (V)380/400380/400380/400
Frequency (Hz)505050
Operating speed (rpm)300030003000
AlternatorSC8SC12SC16
Number of poles222
Insulation classBBB
Voltage regulationDAVRDAVRDAVR
Engine modelCG195FCG1103F-
Engine typeDieselDieselDiesel
Displacement (cc)532733-
Engine power (kW)8.011.715.4
Compression ratio19:119:119:1
Oil capacity (L)1.652.12.8
Starter power (kW)1.21.6-
Battery (V/Ah)-12/3612/36
Fuel tank capacity (L)151528
Fuel consumption at 100% load (L/h), approx.2.202.983.48
Fuel consumption at 75% load (L/h), approx.1.622.382.78
Noise level at 7 m (dB(A))727474
Circuit breakersABBABBABB
CEE 400 V socket1 x 32 A1 x 32 A1 x 32 A
CEE 230 V socket1 x 16 A1 x 16 A1 x 16 A
Schuko sockets2 x 16 A2 x 16 A2 x 16 A
Starting systemElectric key startElectric key startElectric key start
External ATSOptionalOptionalOptional
Length (mm)97011101270
Width (mm)535660670
Height (mm)735935865
Gross weight (kg)178274336